DC - DC Transmitters
|
|
| Download DC Input pdf |
| Model
| Input
| Output
| Power |
API 2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Strain Gauge
See data sheet for input specifications and model numbers
| Specify Output Range for Each Channel
Factory Configured
0-1 V,
0-5 V,
1-5 V,
0-10 V
±5 V,
±10 V
0-1 mA,
0-20 mA,
4-20 mA
Others available
| Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC, 48-300 VDC Power
API 20xx DD for 9-30 VDC,
10-32 VAC Power (+$60) |
API 4010 G
DC-DC Transmitter, Non-Isolated
|
| DC Voltage or Current
Specify Range
18V Loop Supply
| DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4050 G
DC-DC Transmitter, Non-Isolated
Narrow Input Span
| DC Voltage or Current
Specify Range
Narrow Input Span
18V Loop Supply
| DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
APD 4300
APD 4300 PLC
Factory Ranged
Isolated DC-DC Transmitter
with I/O Loop Power Supplies
APD 4300 PLC is pre-configured
for 4-20 mA I/O
Isolate Single-Ended Inputs,
Eliminate PLC/DCS Ground Loops
Isolate and Correct Sink-Sink o
r Source-Source Mismatches
Use with Allen Bradley, GE/Fanuc,
IDEC, Omron, Mitsubishi, Modicon,
Siemens, Panasonic,
Honeywell Analog Inputs
|
Removable Plugs!

| Specify Input Range
Factory Configured
0-100 mVDC to
0-100 VDC
±100 mVDC to ±10 VDC
0-1 mADC to
0-900 mADC
4-20 mA Input
Others available
Milliamp input can be field wired for sink or source
| Specify Output Range
Factory Configured
0-1 V to ±10 VDC,
0-1 mA to 4-20 mA,
up to 20 VDC with M09 option,
4-20 mA Output
Others available
Milliamp output can be field wired for sink or source
| Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Output Test Terminals for
Manual Override Capability
Full I/O/Power Isolation
Selectable I/O Sink/Source
15 V Input Loop Power Supply
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC,
10-32 VAC Power |
API 4300 G
DC-DC Transmitter, Isolated
|
| DC Voltage or Current
Factory Set Range
18V Loop Supply
| Fully Isolated
DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4310 G
DC-DC Transmitter, Isolated
Narrow Input Span
| DC Voltage or Current
Specify Range
Narrow Input Range
18V Loop Supply
| Fully Isolated
DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4380 G
DC-DC Transmitter, Isolated
Field Rangeable
4380 G Ranges
4380 G Help
|
| DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully Isolated
C Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4380 GHV3
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable
4380 GHV3 Ranges
| DC Voltage or Current
Field Selectable Ranges
High Voltage Input to
200 VDC
18V Loop Supply
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4380 DIN
DC-DC Transmitter, Isolated
Field Rangeable
4380 DIN Help
|
| DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 80-265 VAC
48-300 VDC |
API 4380 DD
DC-DC Transmitter, Isolated
Field Rangeable
4380 DIN Help
| DC Voltage or Current
Field Selectable Ranges
12V Loop Supply
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 9-30 VDC |
APD 4380
Field Selectable Minuteman Setup Isolated DC-DC Transmitter
|
Removable Plugs!
| 53 Field Configurable Input Ranges
0-10 mVDC to 0-50 VDC
±10 mV to ±10 VDC
0-200 µA to 0-50 mADC
Others available
| 18 Field Configurable Output Ranges
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
Others available
| Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable I/O Sink/Source
15 V Input Loop Power Supply
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC,
10-32 VAC Power |
API 4385 G
DC-DC Transmitter, Isolated
Field Rangeable
4385 G Ranges
|
| DC Voltage or Current
Field Selectable Ranges
True Offset
Non-Interacting Controls
18V Loop Supply
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
APD HV-DC
Fast Field Selectable Setup
Isolated DC-DC Transmitter for High Voltage DC Inputs
|
Removable Plugs!
| 8 Field Configurable Input Ranges
7 standard plus 1 factory set custom range (specify if required)
0-100 VDC,
0-200 VDC,
0-300 VDC,
0-400 VDC,
0-500 VDC,
0-1000 VDC,
0-1200 VDC, custom
| 18 Field Configurable Output Ranges
0-1 V, 0-2 V, 0-4 V,
1-5 V, 0-5 V, 0-8 V,
2-10 V, 0-10 V,
±5 V, ±10 V,
0-2 mA, 0-4 mA,
0-8 mA, 2-10 mA,
0-10 mA, 0-16 mA,
4-20 mA, 0-20 mA
| I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN rail mount
22.5 mm Wide
80-265 VAC or 48-300
VDC Powered
APD HV-DC D for 9-30 VDC
/ 10-32 VAC Power |
DPI HV-DC
Hi Voltage DC-DC Transmitter,
Isolated
Field Rangeable
DPI HV-DC Ranges
|
| High Voltage DC
0-100VDC to 0-1200VDC
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
API 4390
2 Channel DC-DC Transmitter,
Isolated
|
| DC Volts or mA
2 Independent Channels
| Fully Isolated
DC Voltage or Current
2 Independent Channels
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API 4391
2 Channel DC-DC Transmitter,
Isolated, Bipolar Output
|
| DC Volts or mA
2 Independent Channels
| Fully Isolated
Bipolar 5 Volts or 10 Volts
2 Independent Channels
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API 4392
2 Channel DC-DC Transmitter,
Isolated, Bipolar Input & Output
|
| Bipolar DC Volts or mA
2 Independent Channels
| Fully Isolated
Bipolar DC Volts or mA
2 Independent Channels
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API 4393
IsoSplitter
DC-DC Signal Splitter,
Isolated
|
| One DC Voltage or Current
| Fully Isolated
Two Independent
DC Voltage or
Current Channels
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API 4393 L1
IsoSplitter
DC-DC Signal Splitter,
Isolated
Sourced Input,
Source or Sink Outputs
|
| One 4-20 mA
18V Loop Power Supply
| Fully Isolated
Two Independent
4-20 mA Channels
Source or Sink Outputs
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VAC/VDC |
API 4393 DIN
IsoSplitter
DC-DC Signal Isolator-Splitter
Sink-Source-Source
|
| Specify Input Range
Factory Configured
0-50mVDC to ±10VDC
0-1mADC to
0-20mADC,
4-20mADC
Current Inputs are Sinking
Others available
| Specify Output Ranges
Factory Configured
2 Independent Channels
0-50mVDC to ±10VDC
0-1mADC to
0-20mADC,
4-20mADC
Current Outputs use 15V Source for each Channel
Others available
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN EX1
IsoSplitter
4-20 mA Signal Isolator-Splitter
Sink-Sink-Source
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: 4-20 mA, Current Sinking
Ch.2: Specify Output Range
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN EX2
IsoSplitter
4-20 mA Signal Isolator-Splitter
Sink-Source-Sink
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: 4-20 mA, 15 V Source
Ch.2: 4-20 mA, Current Sinking
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN EX3
IsoSplitter
4-20 mA Signal Isolator-Splitter
Sink-Sink-Sink
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: 4-20 mA, Current Sinking
Ch.2: 4-20 mA, Current Sinking
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN L1
IsoSplitter
4-20 mA Signal Isolator-Splitter
Source-Source-Source
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: Specify Output Range
Ch.2: Specify Output Range
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN L1 EX1
IsoSplitter
4-20 mA Signal Isolator-Splitter
Source-Sink-Source
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: 4-20 mA, Current Sinking
Ch.2: Specify Output Range
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN L1 EX2
IsoSplitter
4-20 mA Signal Isolator-Splitter
Source-Source-Sink
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: Specify Output Range
Ch.2: 4-20 mA, Current Sinking
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
API 4393 DIN L1 EX3
IsoSplitter
4-20 mA Signal Isolator-Splitter
Source-Sink-Sink
|
| Factory Configured
One 4-20 mA Sinking Input
| Factory Configured
2 Independent Channels
Ch.1: 4-20 mA, Current Sinking
Ch.2: 4-20 mA, Current Sinking
| Removable Plugs
I/O Loop Tracker LEDs
Output Test Button
Full I/O/Power Isolation
DIN Rail or Surface Mount
55 mm Wide
115 VAC Powered
A230 option for 230 VAC Power
D option for 9-30 VDC Power (+$60) |
|
Loop-Powered Isolators
|
|
| Download DC Input pdf |
| Model
| Input
| Output
| Power |
API LPI-1
Loop-Powered Isolator
|
| 4-20 mA
| Fully Isolated
4-20 mA
| Loop Powered |
API LPI-2
Dual Channel
Loop-Powered Isolator
| Two 4-20 mA
| Fully Isolated
Two 4-20 mA
| Loop Powered |
DPI-2
Dual Channel
Loop-Powered Isolator
|
| Two 4-20 mA
| Fully Isolated
Two 4-20 mA
| Loop Powered |
Sineax DCM 817-4
Loop-Powered Isolator

Sineax DCM 817-5
PCB Mount Isolator 90° Pins
|
| 0-20 mA, 4-20 mA
| 0-20 mA, 4-20 mA
| 500 V Isolation
Circuit Board Mounted
Straight Pins or 90° Pins
Loop-Powered Passive Device
600 O Maximum Burden
Compact and Cost Effective
OEM Solution
Specifications |
Sineax TI816
PCB Mount Isolator
Straight Pins

Sineax TI816
Loop-Powered Isolator
Voltage Output
|
| 0-20 mA, 4-20 mA
| 0-10 V to 2-10 V
| 500 V Isolation
Loop-Powered Passive Device
Order with V or mA Output
600 O Maximum Burden (Current)
500 O Maximum Burden (Voltage)
Only 0.5" (12.5 mm) Wide
Low Cost
Specifications
Instructions
|
Sineax SI 815
Loop-Powered Isolator
|
| 4-20 mA
| 4-20 mA
| 2300 V Isolation
Single and Two Channel Versions
Output Loop Powered (12-30 V)
Transfers Power to Input Loop
Optional HART Protocol
Specifications
Instructions
|
Sineax SI 815
2 Channel Loop-Powered Isolator
|
| 4-20 mA
| 4-20 mA
| 2300 V Isolation
Single and Two Channel Versions
Output Loop Powered (12-30 V)
Transfers Power to Input Loop
Optional HART Protocol
Specifications
Instructions
|
Sineax TI 807-5
Loop-Powered Isolator, 1 Channel
|
| 0-20 mA, 4-20 mA
| 0-20 mA, 4-20 mA
| Up to 4000 V Isolation
Loop-Powered Passive Device
One, Two, or Three Channel Versions
1000 O Maximum Burden
Specifications
Instructions
|
Sineax TI 807-112
Loop-Powered Isolator
2 Channel

Sineax TI 807-113
Loop-Powered Isolator
3 Channel
|
| 0-20 mA, 4-20 mA
| 0-20 mA, 4-20 mA
| Up to 4000 V Isolation
Loop-Powered Passive Device
One, Two, or Three Channel Versions
1000 O Maximum Burden
Specifications
Instructions |
|
Loop Power Supplies
|
|
| |
| Model
| Input
| Output
| Power |
API 9046
Regulated DC Power Supplies
|

|
115 VAC Std.
Opt. 230 VAC
|
Specify Output Voltage
Factory Configured
Others available
9046-05 0-5V 250mA
9046-06 0-6V 200mA
9046-09 0-9V 150mA
9046-10 0-10V 140mA
9046-12 0-12V 125mA
9046-15 0-15V 100mA
9046-18 0-18V 85mA
9046-24 0-24V 75mA
9046-28 0-28V 60mA
9046-32 0-32V 50mA
|
Hot-Swappable Plug-In Design
Lifetime Warranty
Power LED
Regulated Output
Output Fine Adjustment
Uses API-008 8-Pin Socket
Specify Power,
115 VAC or 230 VAC
|
API 9046 CH
Regulated Bipolar DC Power Supplies
|
115 VAC Std.
Opt. 230 VAC
|
Specify Output Voltage
Factory Configured
Others available
9046 CH-05 ±5V 125mA
9046 CH-06 ±6V 100mA
9046 CH-12 ±12V 60mA
9046 CH-15 ±15V 50mA
|
Hot-Swappable Plug-In Design
Lifetime Warranty
Power LED
Regulated Output
Uses API-008 8-Pin Socket
Specify Power; 115VAC or 230VAC |
| Sineax B 812
Loop Power Supply with I/O Isolation
and Hart
|
| Factory configured for
60-265 VAC or VDC power
| Input side; 4-20 mA,
18 to 25.5 VDC
Source resistance
330 Ω
Output side; 4-20 mA,
17 VDC no load
Permitted load:
750 Ω
, 550 Ω
with HART
| 3.6 kV Input, Output, and Power
Isolation
Red LED for Open and Short
Circuit Fault Detection
Designed for HART Protocol
Specify Power, 60-265 VAC/VDC
or 20-70 VAC/VDC

Specifications
Instructions
|
| Sineax B 812
Loop Power Supply with I/O Isolation
and Hart
|
| Factory configured for
20-70 VAC or VDC power
| Input side; 4-20 mA,
18 to 25.5 VDC
Source resistance
330 Ω
Output side; 4-20 mA,
17 VDC no load
Permitted load:
750 Ω
, 550 Ω
with HART
| 3.6 kV Input, Output, and Powe
r Isolation
Red LED for Open and Short
Circuit Fault Detection
Designed for HART Protocol
Specify Power, 60-265 VAC/VDC
or 20-70 VAC/VDC

Specifications
Instructions
|
| Sineax B 840
4 Channel Loop Power Supply
|
| Factory configured for
24 VAC,
115 VAC, or 230 VAC power
| 4-20 mA, 24 VDC
4 Independent 4-20 mA Loops
| 4-Channel 4-20 mA, 24V DC Versions
LED Monitor for Each Channel
Each Channel Isolated
30 mA Current Limiter for Each Channel
Specify Power, 24 VAC, 115 VAC, or 230 VAC
Specifications
Instructions
|
|
Thermocouple Input
|
|
| Download Temperature Input pdf |
| Model
| Input
| Output
| Power |
API 1200 G
T/C Input DPDT Alarm
|
| J, K, T, E Thermocouple
Specify Type & Range
| 1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 1220 G
T/C Input Dual SPDT Alarms
| J, K, T, E Thermocouple
Specify Type & Range
| 2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| Sineax V624
Programmable
Isolated RTD or
T/C to DC Transmitter
Microprocessor Based

|
| RTD
2-, 3-, or 4-wire
100 Ω 0.00385a
100 Ω 0.003916a
T/C types
J, K, T, E, R, S, N, B, W5, W3, L, U
Thermistor
Custom
| Specify if Current or Voltage
Output
0-2 mA to
0-20 mA,
20-0 mA
0-1 V to
0-10 V,
10-0 V
| PC Programmable
Reverse Output Programmable
Custom Input Linearization
Programmable Sensor Fault Response
Removable Plugs
3.7 kV Input/Output/Power Isolation
24-60 or 85-230 VAC/VDC Powered
Software
Instructions
|
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced by
Camille Bauer V624
|
| J, K, T, E, R, S Thermocouple
Most RTDs &
Resistance Elements
Field Selectable Type & Range
|
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API 4100 G
T/C Input Transmitter,
Non-Isolated, Non-Linearized
|
| J, K, T, E Thermocouple
Specify Type & Range
|
DC Voltage or Current
Field Selectable Ranges
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API 4130 GL
T/C Input Transmitter,
Isolated, Linearized
| J, K, T, E Thermocouple
Specify Type & Range
|
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
|
RTD Input
|
|
| Download Temperature Input pdf |
| Model
| Input
| Output
| Power |
| Sineax V624
Programmable
Isolated RTD or
T/C to DC Transmitter
Microprocessor Based

|
| RTD
2-, 3-, or 4-wire
100 Ω 0.00385a
100 Ω 0.003916a
T/C types
J, K, T, E, R, S, N, B, W5, W3, L, U
Thermistor
Custom
| Specify if Current or Voltage
Output
0-2 mA to
0-20 mA,
20-0 mA
0-1 V to
0-10 V,
10-0 V
| PC Programmable
Reverse Output Programmable
Custom Input Linearization
Programmable Sensor Fault Response
Removable Plugs
3.7 kV Input/Output/Power Isolation
24-60 or 85-230 VAC/VDC Powered
Software
Instructions
|
APD 1400
RTD Input Single Alarm Trip
|
| Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385a
100 Ω 0.00391a,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special
| Single setpoint dual SPDT Form C 8A contact set
Field Adjustable
Specify Alarm Type
Standard: HI alarm, non-latching, normal acting
Options: LO alarm, latching, reverse acting
See data sheet for alarm options
| DIN Rail Mount without Tools
LoopTracker LED for Input
Alarm Status LEDs
Push to Test/Reset
2-Wire or 3-Wire RTD
Lead Wire Compensation for 3-Wire
Universal Power
D option for 9-30 VDC, 10-32 VAC Power |
APD 1420
RTD Input Dual Alarm Trip

|
| Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385a
100 Ω 0.00391a,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special
| Two setpoint dual SPDT Form C 8A contact sets
Field Adjustable
Specify Alarm Type
Standard: HI/LO alarm, non-latching, normal acting
Options: LO/LO, HI/HI, LO/HI alarms, latching, reverse acting
See data sheet for alarm options
| DIN Rail Mount without Tools
LoopTracker LED for Input
Alarm Status LEDs
Push to Test/Reset
2-Wire or 3-Wire RTD
Lead Wire Compensation for 3-Wire
Universal Power
D option for 9-30 VDC, 10-32 VAC Power |
APD 1430
RTD Input Band Alarm Trip

|
| Specify RTD type and Temperature Range
Factory Configured
10 Ω to 2000 Ω RTD including
100 Ω 0.00385a
100 Ω 0.00391a,
10 Ω Cu,
1000 Ω Ni-Fe,
120 Ω Ni or Special
| Two setpoint dual SPDT Form C 8A contact sets
Field Adjustable
Specify Alarm Options
Standard: Band alarm (both alarms trip if outside LO and HI
trip points), non-latching, normal acting
Options: Inverse band alarm, latching, reverse acting
See data sheet for alarm options
| DIN Rail Mount without Tools
LoopTracker LED for Input
Alarm Status LEDs
Push to Test/Reset
2-Wire or 3-Wire RTD
Lead Wire Compensation for 3-Wire
Universal Power
D option for 9-30 VDC, 10-32 VAC Power |
API 1400 G
RTD Input DPDT Alarm
|
| 10 Ω to 2000 Ω RTDs
Factory Set Type & Range
| 1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 1420 G
RTD Input Dual SPDT Alarms
| 10 Ω to 2000 Ω RTDs
Specify Type & Range
| 2 SPDT Contact Sets
Field Adjustable
Specify Alarm Types
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4000 G
T/C or RTD Input Transmitter, Isolated
Field Rangeable
Note: This model discontinued and replaced by
Sineax V624
|
| Most RTDs &
Resistance Elements
J, K, T, E, R, S Thermocouple
Field Selectable Type & Range
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4001 G
RTD Input Transmitter, Non-Isolated,
Non-Linearized
|
| 10 Ω to 2000 Ω RTDs
Specify Type & Range
| DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4001 GL
RTD Input Transmitter, Isolated,
Linearized
| 10 Ω to 2000 Ω RTDs
Specify Type & Range
| Fully Isolated
DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4001 G SA-B
Differential 2 RTD Input Transmitter,
Non-Isolated,
Non-Linearized
|
| Two 100 Ω 0.00385 RTDs
For Differential Temperature
Factory Set,
Can Be Field Calibrated
| DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
T16L Series
(F16LT)
ThermoPro®
Indicating RTD Transmitter
|
|
Specify RTD Length and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
| 4-20 mA Output is User Configurable Over the Temperature Range
| User-Programmable 4-20 mA
Output Range
0.1 Degree Display Resolution
Precision RTD Element
NEMA 4X Housing
2-Wire Design
Powered by 8-32 VDC 4-20 mA
Current Loop
316 Stainless Steel Probe
1/2" NPT Fitting for Standard
Thermowells
Spring-Loaded Probe for use
with Thermowells |
T16B Series
ThermoPro®
Battery Powered RTD
Temperature Indicator
|
|
Specify RTD Length and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
| None
| 0.1 Degree Display Resolution
Precision RTD Element
NEMA 4X Housing
Powered by Two AA batteries (included)
316 Stainless Steel Probe
1/2" NPT Fitting for Standard Thermowells
Spring-Loaded Probe available for use with Thermowells |
T16ADA Series
ThermoPro®
Battery Powered RTD
Temperature Indicator
|
|
Specify RTD Length and Fixed or Spring-Loaded RTD
Temperature Range
58.0°F to 392.0°F or
50.0°C to 200.0°C
Selectable °F or °C
See data sheet for model numbers
| 2 SPDT relays,
1 A @ 24 VDC,
0.5 A @ 115 VAC,
Non-inductive,
Fully programmable
| User-Programmable Alarm Relays
0.1 Degree Display Resolution
Precision RTD Element
NEMA 4X Housing
Powered by 8-32 VDC, 10-32 VAC
316 Stainless Steel Probe
1/2" NPT Fitting for Standard Thermowells
Spring-Loaded Probe for use with Thermowells |
|
Frequency Modules
|
|
|
Click here to download Frequency pdf
|
|
Model
|
Input
|
Output
|
Power
|
API 7010 G
Frequency
to DC Transmitter, Isolated
|
|
10 Hz to 20 KHz
Specify Input Span
|
Fully Isolated
DC Voltage or Current
Specify Range
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API 7500 G
DC to Frequency Transmitter, Isolated
7500 G Ranges
7500 G Help
|
|
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
|
Fully Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API 7500 G SS
DC to Low Frequency Transmitter, Isolated
7500 G SS Ranges
|
DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
|
Fully Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
API 7580 G
Frequency
to DC Transmitter, Isolated
Field Rangeable
7580 G Ranges
7580 G Help
|
|
100 Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
|
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
|
115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC
|
|
Frequency Modules
|
|
| Download Frequency pdf |
| Model
| Input
| Output
| Power |
| APD 7580
Field Selectable Minuteman Setup
Frequency to DC Transmitter
Isolated

|
| 30 Field Configurable Inputs
Low Range
100 Hz Increments
Min: 0-100 Hz
Max: 0-1500 Hz
High Range
2 kHz Increments
Min: 2 kHz
Max: 30 kHz
| 18 Field Configurable Outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
| Accepts most frequency & prox sensors
Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Output Sink/Source
15 V Sensor Power Supply
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power |
API 2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
API 1700 G
Frequency Input DPDT Alarm
|
| 10 Hz to 20 KHz
Specify Input Span
| 1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 1720 G
Frequency Input Dual SPDT Alarms
| 10 Hz to 20 KHz
Specify Input Span
| 2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 7010 G
Frequency to DC Transmitter, Isolated
|
| 10 Hz to 20 KHz
Specify Input Span
|
Fully Isolated
DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 7500 G
DC to Frequency Transmitter, Isolated
7500 G Ranges
7500 G Help
|
| DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully Isolated
0-100 Hz to 0-30 KHz
Field Selectable
Specify Open Col. or TTL
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 7500 G SS
DC to Low Frequency Transmitter, Isolated
7500 G SS Ranges
| DC Voltage or Current
Field Selectable Ranges
18V Loop Supply
| Fully Isolated
0-1 Hz to 0-300 Hz
Field Selectable
Specify Open Col. or TTL
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 7580 G
Frequency to DC Transmitter, Isolated
Field Rangeable
7580 G Ranges
7580 G Help
|
| 100 Hz to 30 KHz
Field Selectable Ranges
18V Loop Supply
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| RheinTacho Speed Monitors
CR
CRR
CRA
CRRA
Field Programmable
Isolated
 
|
| Programmable
Min: 0-0.01 Hz
Max: 0-20,000 Hz
Optional Sensors:
Hall
Differential Hall
Magnetoresistive
See price list for standard sensors
| CR: 1 Relay
CRR: 2 Relays
CRA: 1 Relay & Analog Output
CRRA 2 Relays & Analog Output
Relay:
5A @ 250 VAC resistive or
2A @ 42 VDC resistive
Analog Output:
0-20mA or 4-20mA
| Field Programmable
DIN-rail mounted
Programmable Measuring Units
Programmable Relays
Programmable Delay and Reset
Full I/O/Power Isolation
18-36 VDC Powered
Instructions
|
|
Potentiometer Input
|
|
| Download Potentiometer Input pdf |
| Model
| Input
| Output
| Power |
API 2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
API 1800 G
Potentiometer Input DPDT Alarm
|
| 0-100 Ω to
0-1 Mega Ω
Potentiometer
| 1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 1820 G
Potentiometer Input Dual SPDT Alarms
| 0-100 Ω to
0-1 Mega Ω
Potentiometer
| 2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4003 G
Potentiometer to DC Transmitter,
Non-Isolated
|
| 0-100 Ω to
0-1 Mega Ω
Potentiometer
| DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4003 G I
Potentiometer to DC Transmitter,
Isolated
| 0-100 Ω to
0-1 Mega Ω
Potentiometer
| Fully Isolated
DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4008 G
Potentiometer to DC Transmitter,
Isolated
Field Rangeable
|
| 0-100 Ω to
0-1 Mega Ω
Potentiometer
| Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| APD 4008
Field Selectable Minuteman Setup
Isolated Potentiometer to DC Transmitter
|
| Any Potentiometer
0-100 O to
0-1 Mega Ω
0 to 90% Offset Capable
Can Use Partial Potentiometer Ranges
| 18 Field Configurable Outputs
0-1 V to ±10 V
0-2 mA to 0-20 mA
4-20 mA
| Minuteman One-Minute Setup
Removable Plugs
I/O LoopTracker LEDs
Output Test Button
Full I/O/Power Isolation
Selectable Output Sink/Source
20 V Output Loop Power Supply
80-265 VAC, 48-300 VDC Powered
D option for 9-30 VDC, 10-32 VAC Power
|
|
Strain Gauge, Bridge, Load Cell Input
|
|
| Download Strain Gauge Input pdf |
| Model
| Input
| Output
| Power |
API 1500 G
Strain Gauge Input DPDT Alarm
|
| Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
| 1 DPDT Contact Set
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 1520 G
Strain Gauge Input Dual SPDT Alarms
| 2 SPDT Contact Sets
Field Adjustable
Specify Alarm Type
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4051 G
Single Strain Gauge to
DC Transmitter,
Non-Isolated
|
| Strain Gauge, Bridge,
Load Cell
Adjustable Excitation
Specify Input Span
| DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4058 G
1-4 Strain Gauge to
DC Transmitter,
Non-Isolated
4058 G Ranges
4058 G Help
|
| 1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4059 G
1-4 Strain Gauge to
DC Transmitter, Isolated
4059 G Help
4059 G Ranges
|
| 1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
| APD 4059
Field Selectable Minuteman Setup
Isolated Bridge to DC Transmitter
Isolated

|
| Field Configurable
0-5 mVDC to
0-400 mVDC
Field Settable Excitation Voltage
0-10 VDC in 1 VDC Steps
| 18 Field Configurable Outputs
0-1 V to ±1 0V
0-2 mA to 0-2 0mA
4-20 mA
| Minuteman One-Minute Setup
I/O LoopTracker LEDs
Full I/O/Power Isolation
Internal Bridge Excitation Source
Drive up to 4 bridges
Output Test Button
DIN rail mount
22.5 mm Wide
80-265 VAC, 48-300 VDC Powered
Option D for 9-30 VDC, 10-32 VAC Power |
API 2000 Series
DuoPak®
Two Channel Isolated Transmitter
|
| Specify Input Type and Range for Each Channel
Factory Configured
Choose Any Two:
DC voltage or current
AC voltage or current
RTD
Frequency
Potentiometer
Load Cell/Strain Gauge
See data sheet for input specifications and model numbers
| Specify Output Range for Each Channel
Factory Configured
0-1 V, 0-5 V,
1-5 V, 0-10 V
±5 V, ±10 V
0-1 mA, 0-20 mA, 4-20 mA
Others available
| Two Independent Channels
I/O LoopTracker LEDs
Output Test Buttons
Full I/O/Power Isolation
Removable Plugs
DIN Rail or Surface Mount
55 mm Wide
80-265 VAC or 48-300 VDC Powered
API 20xx DD for 9-30 VDC/
10-32 VAC Power (+$60)
|
|
API 4059 DIN
1-4 Strain Gauge to
DC Transmitter, Isolated
4059 DIN Ranges
|
| 1 to 4 Strain Gauges,
Bridges, or Load Cells
Field Selectable Ranges
Adjustable Excitation
|
Fully Isolated
DC Voltage or Current
Field Selectable Ranges
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API SUM 000
Strain Gauge Summing Board
API SUM 025
Summing Board with API 4059
API SUM 100
Summing Board w. NEMA 4X Box
API SUM 125
Summing Board, API 4059, NEMA 4X Box
|
| Summing Assembly Board
1 to 4 Strain Gauges,
Bridges, or Load Cells
Individually Adjustable
Excitation & Signal Trim
Optional SS Housing
|
DC Voltage or Current
Use with 4058 G or
4059 G
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
|
Valve
Position, Math & P-1 Converters
|
|
| Download Valve/Math pdf |
| Model
| Input
| Output
| Power |
API 3200 G
Valve Positioner/Actuator
|
| Specify input range
Factory configured
0-1 VDC to
0-100 VDC
0-10 mADC to
0-1 ADC
Potentiometer feedback
| 7 A (3.5 A inductive) SPDT
relay with nNeutral contact position
| Hot-swappable plug-In design
LoopTracker LED for input
Relay LED
Manual open/close
Uses API-011 11-pin socket
115 VAC powered
A230 option for 230 VAC power
D option for 9-30 VDC power (+$60) |
| API 3200 G M01
Valve Actuator/ Positioner/Controller
Voltage Feedback
|
| Specify Input Range
Factory configured
0-1 VDC to
0-100 VDC
0-10 mADC to
0-1 ADC
1-5 V feedback or specify
| 7 A (3.5 A inductive) SPDT
relay with nNeutral contact position
| Hot-swappable plug-In design
LoopTracker LED for input
Relay LED
Manual open/close
Uses API-011 11-pin socket
115 VAC powered
A230 option for 230 VAC power
D option for 9-30 VDC power (+$60) |
| API 3200 G M02
Valve Actuator/ Positioner/Controller
Current Feedback
|
| Specify Input Range
Factory configured
0-1 VDC to
0-100 VDC
0-10 mADC to
0-1 ADC
4-20 mA feedback or specify
| 7 A (3.5 A inductive) SPDT
relay with nNeutral contact position
| Hot-swappable plug-In design
LoopTracker LED for input
Relay LED
Manual open/close
Uses API-011 11-pin socket
115 VAC powered
A230 option for 230 VAC power
D option for 9-30 VDC power (+$60) |
API 4400 G
(A+B+C+D) / 4
API 4401 G
(A+B+C) / 3
API 4402 G
(A+B) / 2
API 4403 G
(A+B+CD) / 3
API 4404 G
(A+BCD) / 4
API 4405 G
(ABCD)
API 4406 G
(A+BC) / 2
API 4407 G
(ABC)
API 4408 G
(AB)
|
| Up to 4 DC Voltage or
Current Inputs
Specify Ranges
| Addition, Subtraction,
Averaging Versions
Fully Isolated
DC Voltage or Current
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
API 4440 G
DC to DC Transmitter,
Square Root Extraction
|
| DC Voltage or Current
Specify Range
18V Loop Supply
| Square Root Extraction
Full Isolated
DC Voltage or Current
Square Root of Input
Specify Range
| 115 VAC Std.
Opt. 230 VAC
Opt. 9-30 VDC |
DPG1000L3-15PSIG
Pressure to Current Converter
|
| 3.00 to 15.00 psig
| 4-20 mA
| Loop Powered |
F4L3-15PSIG
Pressure to Current Converter,
NEMA 4X
|
| 3.00 to 15.00 psig
| 4-20 mA
| Loop Powered |
F16L3-15PSIG
Programmable Pressure
to Current Converter
|
| 3.00 to 15.00 psig
Air Pressure
Other ranges available
| Programmable
2-wire 4-20mA Loop-Powered
| 2-Wire Loop Powered
Output Test Button
±0.25% Accuracy
316SS Sensor
1 Year Warranty |
| F16LN3-15PSIG
Programmable
Pressure to Current Converter
NEMA 4X
|
| 3.00 to 15.00 psig
Air Pressure
Other ranges available
| Programmable
2-wire 4-20mA Loop-Powered
| NEMA 4X housing
2-Wire Loop Powered
Output Test Button
±0.25% Accuracy
316SS Sensor
1 Year Warranty |